{"product_id":"maretron-submersible-pressure-transducer-0-3-psi-pts-0-3psi-02","title":"Maretron Submersible Pressure Transducer 0-3 PSI [PTS-0-3PSI-02]","description":" \u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSubmersible Pressure Transducer 0-3 PSI\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eMaretron’s submersible pressure transducers indicate tank levels and can be installed directly in the tank. Please follow these instructions to mount and connect a submersible pressure transducer to an NMEA 2000® network via a Maretron FPM100 Fluid Pressure Monitor. Maretron recommends one of two methods for mounting a submersible pressure transducer in a tank: 1) without a restraining tube, and 2) with a restraining tube.\u003c\/p\u003e\u003cp\u003eThe submersible pressure transducers are designed for a tank with a 5-hole SAE J1810 fitting at the top. Install the mounting plate with cord grip onto the transducer cable, with the rounded hex section of the cord grip facing away from the transducer.\u003c\/p\u003e\u003cp\u003eLower the pressure transducer into the tank such that the transducer lies at the lowest point of the tank and tighten the cord grip to secure the cable. On a tank with a flat bottom, the transducer may slide from side to side with the motion of the vessel but will not rotate due to the stiffness of the cable. It is also possible to mount the pressure transducer inside a restraining or focus tube (sold separately, Maretron part number TFT-5H).\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePressure Transducer Mounting\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eConnect the two wires of the pressure transducer to a free pressure monitoring channel. Connect the red wire from the pressure transducer to the channel's positive (+) terminal and connect the black wire from the pressure transducer to the negative (-) terminal of the channel. The example in Figure 1 shows the pressure transducer connected to switch channel 0, with the white wire connected to \"P0+\" and the brown wire connected to \"P0-.\" Submersible pressure transducers have a small plastic vent tube in the connecting cable.\u003c\/p\u003e\u003cp\u003eUse a Maretron DSM Series Display (firmware 1.4.7 or higher) or a PC running Maretron’s N2KAnalyzer software (version 1.4.19 or higher) to configure the connected channel(s) on the FPM100.\u003c\/p\u003e\u003cp\u003eSupply power to the NMEA 2000 network and verify that the pressure channel indicates a valid pressure reading.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eOperating Range: 0 to 3 PSI (0.207 bar)\u003c\/li\u003e\n\u003cli\u003eDepth Range (Water): 83.1” (2.11 m)\u003c\/li\u003e\n\u003cli\u003eDepth Range Diesel (820 kg\/m3): 101.3” (2.57 m)\u003c\/li\u003e\n\u003cli\u003eDepth Range Gasoline\/Petrol (750 kg\/m3): 110.8” (2.81 m)\u003c\/li\u003e\n\u003cli\u003eCable Length: 17 ft (5.18 m)\u003c\/li\u003e\n\u003cli\u003eSensor Type: Gauge (Vent Tube)\u003c\/li\u003e\n\u003cli\u003eOutput: 4 – 20 mA current loop, loop powered\u003c\/li\u003e\n\u003cli\u003eExcitation Voltage: 8 VDC to 28 VDC\u003c\/li\u003e\n\u003cli\u003eCompatible Fluids \/ Gases: Diesel, Diesel Exhaust Fluid (DEF), Gasoline\/Petrol, Hydraulic Fluid, Kerosene, Motor Oil, Fresh Water, Sea Water, Waste Water\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: 14 degrees F to 158 degrees F (-10 degrees C to 80 degrees C)\u003c\/li\u003e\n\u003cli\u003eStorage Temperature: -4 degrees F to 176 degrees F (-20 degrees C to 80 degrees C)\u003c\/li\u003e\n\u003cli\u003eAccuracy: ±0.3% Full Scale typ. at 25°C\u003c\/li\u003e\n\u003cli\u003eTotal Error Band (TEB): ±1.0% Full Scale typ. (-10 degrees C to 70 degrees C)\u003c\/li\u003e\n\u003cli\u003eNon-Linearity, Hysteresis (NLH): ±0.2% Full-Scale typ. Best Straight Line (BSL) at 25°C\u003c\/li\u003e\n\u003cli\u003eTemperature Compensation: 23 degrees F to 122 degrees F (0 degrees C to 50 degrees C)\u003c\/li\u003e\n\u003cli\u003eAccuracy: ±1% Full Scale\u003c\/li\u003e\n\u003cli\u003eLinearity: 0.5% Full Scale\u003c\/li\u003e\n\u003cli\u003eRepeatability: 0.05% Full Scale\u003c\/li\u003e\n\u003cli\u003eFull-Scale Thermal Error: 0.04% Full Scale\/°F (0.07% Full Scale\/degrees C)\u003c\/li\u003e\n\u003cli\u003eLong-Term Stability: 0.2% Full Scale\/year\u003c\/li\u003e\n\u003cli\u003eResponse Time: 150ms\u003c\/li\u003e\n\u003cli\u003eProof Pressure: 2 × Full Scale\u003c\/li\u003e\n\u003cli\u003eBurst Pressure: 3 × Full Scale\u003c\/li\u003e\n\u003cli\u003eReverse Voltage Protection: ± 30V for 3 minutes\u003c\/li\u003e\n\u003cli\u003eConstruction: 316L stainless steel body and diaphragm, polyether polyurethane cable, chloroprene boot\u003c\/li\u003e\n\u003cli\u003eEMC Compatibility: 10 Volts\/meter per EN 61000-4-3\u003c\/li\u003e\n\u003cli\u003eWeight: 24.8oz (703g)\u003c\/li\u003e\n\u003c\/ul\u003e \u003c!--- cis2:m2hunZZk ---\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/ownersManual\/102517OM.pdf\" target=\"_blank\"\u003eOwner's Manual (pdf)\u003c\/a\u003e","brand":"Maretron","offers":[{"title":"Default Title","offer_id":44104408563970,"sku":"CWR-102517","price":345.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0637\/4522\/9058\/files\/102517XL.jpg?v=1703197868","url":"https:\/\/www.greaterhappy.com\/products\/maretron-submersible-pressure-transducer-0-3-psi-pts-0-3psi-02","provider":"Greater Happy Outdoors and Health","version":"1.0","type":"link"}